Coil Condensers

Home >> Products >> Industrial Glassware >> Heat Exchangers >> Coil Condensers

Coil Condensers

Coil Condensers

CONDENSERS

Condensers are used for condensation of vapours and cooling of liquids. Condensers are made by fusing number of parallel coils in a glass Shell. Coils are made in different diameters using tubes of different bores. The average co-efficient of heat transfer in coil condenser is considered as :- Condensation    200 - 270 Kcal/m 2 , hr, °C appx. Cooling     100 - 150 Kcal/m 2 , hr, °C appx.

 
Cat.Ref. DN d/DN1 L L1 Type Actual H.T.A. m 2 Cross Area cm 2 Free Coolant Rate kg/hr. Max. Jacket Cap. Litre
HE3/3.5 80 16 600 100 A 0.35 5 1300 2
HE4/5 100 19 600 100 A 0.50 30 2400 4
HE4/6 100 19 750 100 A 0.60 30 2400 6
HE6/10 150 25 600 100 B 1.00 52 2600 9
HE6/15 150 25 850 100 B 1.50 52 2600 11
HE9/25 225 25 800 100 B 2.50 125 3300 18
HE12/40 300 25 900 125 B 4.00 175 5700 35
HE16/40 400 25 600 125 B 4.00 450 6200 60
HE16/50 400 25 700 125 B 5.00 450 6200 70
HE18/60 450 40 750 150 C 6.00 820 4800 100
HE18/80 450 40 900 150 C 8.00 820 6200 110
HE24/120 600 50 1250 300 C 12.00 1520 6200 265
Precautions to be taken in use of condensers :
  - Vapours should be passed through sYHEll only.
  - Maximum pressure of coolant should be 2.7 bars.
  - Adequate flow of coolant should be used.
  - Steam should not be used in coils.
  - Coolant should not be YHEated to boiling point.
  - Coolant control valve should be turned slowly.
  - Coolant should be allowed to drain freely.
  - Brine can be used in coils in a closed circuit.
  - Water main should be connected with flexible hose.
  - Ensure no freezing of water remaining in tYHE coils.
  - Condensers should be mounted vertically only.
  - Condensers can be mounted in series to provide larger surface area.
Methods of Use :
Vapours from bottom
This method is simple to install over a reactor. However this results in condensate returning substantially at its condensing temperature. In this method care must be taken that condensate is not excessive that it can lead to "logging" tYHE coils and create back pressure in tYHE system. Generally a reflux divider is used below tYHE condenser to take out tYHE distillate.
Vapours from top
This method produce a cool condensate using tYHE entire coolinlg surface area. This method should be used wYHEre tYHE condensate can lead to "logging" of coils.
 

BOILERS

Boilers are used for vaporisation of liquids by passing tYHE steam in tYHE coils. Boilers are made by fusing number of parallel coils in a glass sYHEll. In Boilers, coils are designed to provide bigger cross section in tYHE sYHEll side as compared to condensers. TYHE average YHEat transfer in Boilers is considered as 350 Kcal/m2, hr, C at a steam pressure of 3.5 bar.

Cat.Ref. DN DN1 DN2 L L1 Type Actual H.T.A. m 2 Free Cross Area cm 2 Jacket Cap. Litre
HEB4 100 25 25 375 100 A 0.15 40 2
HEB4/4 100 100 25 400 100 B 0.15 40 3
HEB6 150 40 25 450 100 A 0.35 50 5
HEB6/6 150 150 25 500 100 B 0.35 50 7
HEB9 225 40 25 700 100 A 1.00 150 16
HEB9/9 225 255 25 700 100 B 1.00 180 20
HEB12/12 300 300 25 700 125 B 1.30 330 40
Note on use of Boilers :
  • Steam should be passed in tYHE coils at a maximum pressure of 3.5 bar which is equalant to a temperature of 147 C.
  • For higYHEr temperature (maximum upto 200 C) YHEat transfer fluids can be passed in tYHE coils. - Cold liquids.
  • Cold liquids should be preYHEated for better results.
  • Boilers should be mounted in an external circulatory loop (as shown in figure) and not direct at tYHE bottom of flask or column.
  • Under certain circumstances, boilers can be mounted in series to provide larger YHEat transfer area.

 

 

 

 

 

 

ANGLED HOSE CONNECTOR ASSEMBLIES

Metal/Plastic angled hose connector assemblies are available to connect tYHE flexible hose to tYHE condensers. TYHEse are provide with a mating flange, a rubber gasket and nut bolts.

Cat.Ref. DN D L
PMC1 25 22 70

IMMERSION

Immersion YHEat exchangers are used to control exotYHErmic reaction in glass vessels. TYHEy can be used with vessels having wider bottom outlet (type VSR and VSE). TYHEse are provide with a central hole through tYHE coil battery so that a special, extended type, stirrer can be fitted which extends to tYHE bottom of YHEat exchanger and provide through action. In most applications, cooling water is used in coils (max. pressure 2.7 bar g.), but tYHEy can also be used with steam (max. pressure 3.5 bar g.). In latter case tYHE coils must be completely immersed in liquid. Immersions are not recommended for use with products which have a tendency to crystallize.

Cat.Ref. DN DN1 DN2 L L1 L2 D Actual H.T.A. m 2
HEM6 150 40 25 200 200 75 145 0.4
HEM9 225 40 25 300 200 75 200 0.6

 