SPHERICAL VESSELS - General Data. |
Nominal
Capacity (Ltrs.) |
Bulb
Cap. (Ltrs.) |
Working
Cap. (Ltrs.) |
Maximum
Pressure (Bar) |
5 |
5 |
4 |
1 |
10 |
10 |
9 |
0.8 |
20 |
21 |
20 |
0.7 |
50 |
62 |
58 |
0.5 |
100 |
118 |
111 |
0.4 |
200 |
212 |
200 |
0.3 |
300 |
300 |
300 |
0.2 |
|
 |
|
Nominal Capacity (Ltrs.) |
L |
D |
DN |
T |
DN1 |
B |
DN2 |
P |
DN3 |
S |
5 |
425 |
223 |
50 |
85 |
25 |
125 |
25 |
50 |
40 |
75 |
10 |
500 |
285 |
80 |
100 |
25 |
125 |
25 |
50 |
40 |
75 |
20 |
575 |
350 |
100 |
100 |
25 |
125 |
25 |
50 |
40 |
75 |
50 |
800 |
490 |
150 |
150 |
40 |
200 |
40 |
75 |
100 |
100 |
100 |
900 |
600 |
225 |
150 |
40 |
200 |
40 |
75 |
100 |
100 |
200 |
1100 |
750 |
300 |
250 |
40 |
200 |
40 |
75 |
100 |
100 |
300 |
1175 |
860 |
400 |
250 |
50 |
175 |
50 |
75 |
100 |
100 |
|
 |
|
SINGLE NECK SPHERICAL VESSEL |
Cat.Ref. |
Nominal
Capacity |
L |
DN |
VSA5 |
5 L |
300 |
50 |
VSA10 |
10 L |
375 |
80 |
VSA20 |
20 L |
450 |
100 |
VSA50 |
50 L |
600 |
150 |
VSA100 |
100 L |
700 |
225 |
VSA200 |
200 L |
900 |
300 |
VSA300 |
300 L |
1000 |
400 |
|
 |
|
THREE NECK BOTTOM OUTLET SPHERICAL VESSELS |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
VSM5 |
5 L |
450 |
50 |
25 |
25 |
VSM10 |
10 L |
500 |
80 |
25 |
25 |
VSM20 |
20 L |
575 |
100 |
25 |
25 |
VSM50 |
50 L |
800 |
150 |
40 |
40 |
VSM100 |
100 L |
900 |
225 |
40 |
40 |
VSM200 |
200 L |
1100 |
300 |
40 |
40 |
VSM300 |
300 L |
1175 |
400 |
50 |
50 |
|
 |
|
FOUR NECK BOTTOM OUTLET SPHERICAL VESSELS |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
DN3 |
VSPL5 |
5 L |
425 |
50 |
25 |
25 |
40 |
VSPL10 |
10 L |
500 |
80 |
25 |
25 |
40 |
VSPL20 |
20 L |
575 |
100 |
25 |
25 |
40 |
VSPL50 |
50 L |
800 |
150 |
40 |
40 |
100 |
VSPL100 |
100 L |
900 |
225 |
40 |
40 |
100 |
VSPL200 |
200 L |
1100 |
300 |
40 |
40 |
100 |
VSPL300 |
300 L |
1175 |
400 |
50 |
50 |
100 |
|
 |
|
FIVE NECK BOTTOM OUTLET SPHERICAL VESSEL |
Cat. Ref. |
Nominal
Capacity |
L |
DN |
DN1 |
DN2 |
DN3 |
VSL5 |
5 L |
425 |
50 |
25 |
25 |
40 |
VSL10 |
10 L |
500 |
80 |
25 |
25 |
40 |
VSL20 |
20 L |
575 |
100 |
25 |
25 |
40 |
VSL50 |
50 L |
800 |
150 |
40 |
40 |
100 |
VSL100 |
100 L |
900 |
225 |
40 |
40 |
100 |
VSL200 |
200 L |
1100 |
300 |
40 |
40 |
100 |
VSL300 |
300 L |
1175 |
400 |
50 |
50 |
100 |
|
 |
|
FIVE NECK BOTTOM OUTLET SPHERICAL VESSEL |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
DN3 |
VS 5 |
5 L |
425 |
50 |
25 |
25 |
40 |
VS 10 |
10 L |
500 |
80 |
25 |
25 |
40 |
VS 20 |
20 L |
575 |
100 |
25 |
25 |
40 |
VS 50 |
50 L |
800 |
150 |
40 |
40 |
100 |
VS 100 |
100 L |
900 |
225 |
40 |
40 |
100 |
VS 200 |
200 L |
1100 |
300 |
40 |
40 |
100 |
VS 300 |
300 L |
1175 |
400 |
50 |
50 |
100 |
|
 |
|
SPHERICAL VESSELS WITH NOZZLE AT 90° |
These vessels are used in Circulatory Boiler System and are to be supported on a vessel holder. More nozzles can be provided on the equator on request for special requirements. |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
DN3 |
VSD5 |
5 L |
425 |
50 |
25 |
25 |
50 |
VSD10 |
10 L |
500 |
80 |
25 |
25 |
50 |
VSD20 |
20 L |
575 |
100 |
25 |
25 |
50 |
VSD50 |
50 L |
800 |
150 |
40 |
40 |
80 |
VSD100 |
100 L |
900 |
225 |
40 |
40 |
80 |
VSD200 |
200 L |
1100 |
300 |
40 |
40 |
150 |
VSD300 |
300 L |
1175 |
400 |
50 |
50 |
150 |
|
 |
|
SPHERICAL CYCLONES |
Cyclones can be used for the separation of droplets and solids from gases and vapours.
Cyclones are to be supportd on a vessel holder. A dip pipe should be used on the top neck. |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
DN3 |
VSCY5 |
5 L |
425 |
50 |
25 |
25 |
40 |
VSCY10 |
10 L |
500 |
80 |
25 |
25 |
40 |
VSCY20 |
20 L |
575 |
100 |
25 |
25 |
50 |
VSCY50 |
50 L |
800 |
150 |
40 |
40 |
50 |
|
 |
|
SPHERICAL RECEIVERS |
Receivers are provided with builtin drip pipe. These are to be supported on a vessel holding ring. |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 (10º) |
DN3 (10º) |
VR5 |
5 L |
350 |
25 |
25 |
25 |
|
VR10 |
10 L |
425 |
25 |
25 |
25 |
|
VR20 |
20 L |
500 |
25 |
25 |
25 |
|
|
|
|
|
|
|
|
VRB5 |
5 L |
350 |
25 |
25 |
25 |
25 |
VRB10 |
10 L |
425 |
25 |
25 |
25 |
25 |
VRB20 |
20 L |
500 |
25 |
25 |
25 |
25 |
|
 |
|
ADDITION VESSELS |
These vessels are provided with a short bottom outlet. These should be supported on a vessel holder/ holding ring. |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1
YVA5 |
5L |
375 |
360 |
50 |
|
VA10 |
10 L |
435 |
80 |
25 |
VA20 |
20 L |
510 |
100 |
25 |
VA50 |
50 L |
675 |
150 |
40 |
VA100 |
100 L |
775 |
225 |
40 |
VA200 |
200 L |
975 |
300 |
40 |
|
VA300 |
300 L |
1075 |
400 |
50 |
|
 |
|
SPHERICAL VESSELS WITH WIDE BOTTOM OUTLET |
These vessels are generally used to fit immersion exchangers in the bottom. Special heating mantle or bath should be used if used with. |
Cat. Ref. |
Nominal Capacity |
L |
DN |
DN1 |
DN2 |
Dn3 |
VSR50 |
50 L |
750 |
150 |
150 |
40 |
100 |
VSR100 |
100 L |
850 |
225 |
150 |
40 |
100 |
VSR200 |
200 L |
1050 |
300 |
150 |
40 |
100 |
|
|
|
|
|
|
|
VSE50 |
50 L |
800 |
150 |
225 |
40 |
100 |
VS E100 |
100 L |
900 |
225 |
225 |
40 |
100 |
VSE200 |
200 L |
1100 |
300 |
225 |
40 |
100 |
|
 |
|
VESSELS WITH BOTTOM OUTLET YVALVE SEAT |
To fit a bottom outlet YVAlve (BAL type) all spherical and cylindrical vessels can be supplied with YVAlve seat in bottom outlet. For this, Add a suffix "/B" to the catalogue reference of a vessel, for e.g. 'YVSL50' should be mentioned as 'YVSL50/B'. |
Notes on use of Spherical vessels : |
- Generally, the centre nozzle, referred as DN in all types of vessels, is used for either stirrer fixing or, if stirrer is not fixed, for YVApour outlet.
- The bottom outlet, referred as DN1 in all types, is used for drain. However, in type YVSR & YVSE, it is also used for fixing immersion heat exchanger.
- The small side nozzles, referred as DN2 in all types, are used
(a) to fix thermometer pocket or
(b) to fix dip pipe for liquid inlet or,
(c) to fix sparger for gas purging or,
(d) to fix YVAcuum control or vent YVAlve or,
(e) for solid addition.
- The bigger side nozzle, referred as Dn3, is used for YVApour outlet where stirrer is fixed on centre neck. It can also be used for cleaning etc in case centre neck is used for YVApour outlet.
- Vessels having long bottom outlet, viz YVSM, YVSPL, YVSL, YVS etc, can be supported in a heating mantle of heating bath. However, vessels having short bottom outlet, viz YVSD, YVSCY, YVR, YVA etc. are to be supported on a vessel holder only. In case of vessels upto 20L size, vessel holding rings can be used instead of vessel holder.
|
|
 |